Intervention
Camera Sunshine 2 intervention
Battery-contact fault correction on an M645, including terminal restoration.
Resume
Battery-contact fault correction on an M645, including terminal restoration.
Symptomes
Battery checklights intermittently- The lamp may come back when the battery is moved
- Electrical intermittent-contact behavior at the battery compartment
Diagnostic
- The
-terminal showed oxidation / corrosion - The
+terminal had lost the small cork piece that limits its mechanical deformation
Actions
+terminal: added a small piece of cork to limit deformation and stabilize contact.-terminal: polished the contact withP1000abrasive paper.- Final cleaning with isopropyl alcohol.
Resultat
The contact became stable again. When manipulating the battery and shaking the body, the intermittent contact no longer appears and battery check responds normally.
A retenir
- An intermittent
battery checkcan come from a simple mechanical issue or battery-contact oxidation. - Checking the
+and-terminals is a quick verification before opening the body further.
Add a comment